Neuron-Spectrum-Video
video EEG monitoring system
PDF-file
(zip-archive 864 kb)
|

|
USB connection |
|

|
ISO 9001 quality certificate |
|

|
ISO 13488 quality certificate |
|

|
CE conformance certificate |
|

|
Certificates of conformance to CIS requirements |
|
|
|
General Properties
•
Techniques
•
Delivery Set
•
Specifications
Neuron-Spectrum-Video
General Properties
·
Synchronous long-term recording of EEG and video
·
Video recording from one or two video cameras (short-distance
infrared video camera and general view camera)
·
Night videomonitoring when using video camera with infrared
highlighting
·
Audio information recording from one or two microphones (patient's
microphone and medical staff's microphone)
·
Events marking in the process of recording
·
Synchronous review of recorded EEG and video information on one
(PIP) or two monitors with common/increased speed or by frames
·
Instant positioning of video, basing on EEG temporary slice; EEG
positioning basing on the video frame
·
Instantaneous moving to selected event marker, video fragment or
definite point of time
·
Wide capabilities of recorded EEG mathematical analysis and
brain mapping
·
Editing of recorded video EEG for saving only significant
fragments
·
EEG and video data storing on CD or standard video cassettes
Neuron-Spectrum-Video
Techniques
|
|
Review of video EEG record. Simultaneous review of EEG
traces and short-distance camera picture.
|
|
|
|
|
|
General view camera picture.
|
|
|
|
|
|
Spectral analysis of video EEG fragment.
|
|
|
|
|
Neuron-Spectrum-Video
Delivery Set
·
Analog black-and-white video camera with infrared
highlighting for night videomonitoring on a stand
·
Analog color video camera with optical zooming and remote
control on a stand
·
Electronic unit for conversion of the analog video signal to
the digital one and its input in the PC (video capture card)
·
Electrode system for long-term EEG recording (electrode cap
or set of cup electrodes with the adhesive paste)
·
CD with software
·
User manual
·
Transportation bag |
|
|
Neuron-Spectrum-Video
Specifications (as a part of Neuron-Spectrum-4/EP)
|
Number of EEG channels |
21 |
|
Number of polygraphic channels |
4 |
|
Number of breath channels |
1 |
|
EEG Channels: |
|
Sampling rate per channel |
up to 5000 Hz |
|
Sensitivity (based on software) |
1 – 500 µV/mm |
|
Input range |
13 mV |
|
High pass filter |
0.05 – 2 Hz |
|
Low pass filter |
15, 30, 75, 100, 200 Hz |
|
A/D converter |
16 bit |
|
Common-mode rejection ratio at 10 Hz frequency |
110 dB |
|
Suppression ratio of power frequency by notch filter |
40 dB |
|
Peak-to-peak noise level measured at 10 kΩ resistance |
0.8 µV |
|
Input impedance, not less than |
100 MΩ |
|
Interchannel damping, not less than |
60 dB |
|
Calibration |
Auto |
|
Control of electrode setting according to impedance
measurement |
Yes |
|
Control of ground electrode setting |
Yes |
|
Polygraphic Channels: |
|
Sampling rate per channel |
up to 40000 Hz |
|
High pass filter |
0.05 – 200 Hz |
|
Low pass filter |
35 – 5000 Hz |
|
Sensitivity |
10 – 10000 µV /mm |
|
Input range |
0.2 – 100 mV |
|
Breath Channel: |
|
Bandpass |
0.05 – 35 Hz |
|
Video: |
|
Format of recorded video storage |
MPEG-4 |
|
Format of recorded audio storage |
MPEG-3 |
|
EEG and video synchronization accuracy (when recording
25 frames per second) |
1 frame (40 ns) |
|
Supply Voltage: |
|
Electronic unit |
5 V DC |
|
Desktop PC-based system |
220/230 V AC (50 Hz) / 110 V AC (60 Hz) |
|
Notebook PC-based system |
220/230 V AC (50 Hz) / 110 V AC (60 Hz) / Int. battery |
|
EEG unit power consumption, not more than |
2.8 VA |
|
Interface |
USB |
|
Safety |
BF type |
|
|