Neuron-Spectrum-4/EP
multifunctional 26-channel digital system for EEG; visual, auditory,
somatosensory, cognitive (P300, MMN, CNV) EP and EMG

|

|
USB connection |
|
|
PDF-file |
General Properties
•
Techniques •
Delivery Set •
Specifications
Neuron-Spectrum-4/EP
is a unique system combining 21 EEG and long-latency EP, 4 short-latency EP and
EMG, and 1 breath channels.
Neuron-Spectrum-4/EP General Properties
·
High quality 21-channel EEG/long-latency EP recording in an
unshielded room
·
4 polygraphic (EMG/ECG/EOG) channels, breath channel
·
Flash and reversal pattern VEP, AEP, SSEP, P300, MMN, CNV recording
·
EMG examinations providing (optional)
·
Photic- and auditory stimulators separately control left and right
sides, the possibility of electrical stimulator plugging
·
EEG/EP visualization in an arbitrary (user constructed) monopolar
and bipolar montage
·
EEG traces displaying in the habitual for neurologists form of the
paper record with the familiar sensitivity and paper moving speed
·
Automatic control of electrode setting quality in each channel
according to impedance measurement
·
Indication of electrode setting quality on front panel
·
Qualitative control of electrode setting during EEG recording
·
Recording of any number of functional tests of unlimited duration
·
Amplitude, spectral, periodometrical, correlative and coherent EEG
analysis
·
EEG and EP brain mapping
·
Automatic detection of epileptic activity (automatic search of
spikes and sharp waves with mapping)
·
3-D dipole localization of pathological activity sources (optional)
·
Automatic report generation (EEG text description)
·
Possibility of standard electrode cap plugging
·
USB interface allows using Notebooks for the creation of portable
EEG systems
Neuron-Spectrum-4/EP Techniques
|
|
Split
screen mode allows viewing two EEG fragments simultaneously (for example
two different functional tests)
This mode
is very useful for visual comparison of different EEG fragments both in
process of recording and reviewing. |
|
|
|
|
|
Creation
and editing of EEG montages
EEG can be
displayed in any montage chosen by the user (monopolar, bipolar and
mixed). With the help of this mode it is possible to create arbitrary
montages. It can be used for changing of EEG traces displaying in the
process of recording and reviewing. |
|
|
|
|
|
EEG
coherent analysis results
To the
left are the coherency maps, and to the right are the coherency function
graphs for each derivation pair. By moving the marker, user can specify
the instantaneous frequency value. Before the coherent analysis the user
is offered to choose the derivation pairs between which the coherency
parameters will be calculated. The lines color on the maps is defined by
the values of the one coherency parameters (user selected). The closer
is the color of line to the red one, the higher is the value of the
corresponding parameter (the higher is the coherency). As the parameters
the value of the coherency on the instantaneous frequency (in the point
ticked by the marker) or in the frequency ranges can serve. As a
frequency range it is possible to choose either one of the standard
ranges (delta, teta, alpha and beta) or total range of EEG. |
|
|
|
|
|
Spectral
and coherent EEG analysis results
In the
right half of the window, coherency function graphs for selected
derivation pairs are presented. In the left one there are graphs of
spectrum power for each EEG derivation. On the frequency axis the
standard EEG frequency ranges are marked by the color (delta, theta,
alpha and beta). The frequency markers on both graphs can be moved
synchronously. |
|
|
|
|
|
EEG
analysis results
In the
left part of the window, graphs of spectrum power for each derivation,
shown in the one overall coordinate space, are presented. In the right
one graphs of coherency function for selected pairs, also drawn in one
overall coordinate space, are given. The frequency markers on both
graphs can be moved synchronously. |
|
|
|
|
|
Review
and analysis of multi-channel EP
The
software module Neuron-Spectrum-LEP allows providing the
recording and analysis of visual (flash and reversal pattern), auditory
and cognitive (Р300, MNM, CNV) long-latency evoked potentials with their
brain mapping. To the right the averaged EP traces with the set
component markers are displayed. To the left the brain maps of EP
amplitude for each EP component are represented. |
|
|
|
|
|
EEG
checkup report
In
Neuron-Spectrum software the report is generated automatically
basing on the results of EEG mathematical analysis. The report can be
edited in the built-in or MS Word editor. The report contains the
textual description of background EEG and the description of functional
tests responses. If it is necessary, it can be supplemented with EEG
fragments, tables, graphs and brain maps. |
|
|
|
|
|
EEG
analysis results are displayed as brain maps and bar charts
Neuron-Spectrum
software allows carrying out of amplitude, spectral, periodometrical,
correlative, and coherent EEG analysis. The analysis results can be
represented as tables, graphs, bar charts or brain maps. |
|
|
|
|
|
Results
of epileptiform activity analysis (automatic search of spikes and sharp
waves)
Epiactivity analysis can be conducted in a whole record, separate
functional test or EEG fragment. The fragments with detected spikes and
sharp waves are marked by the color. In the result window tables and
epiactivity brain maps are shown. |
|
|
|
|
|
3-D
dipole localization of pathological electrical activity sources
BrainLoc
3-D localization software can be used as an optional module for
Neuron-Spectrum EEG systems. The localization results can be
presented on 3-D head model, on the diagrammatic sectional views of the
brain structures or on the axial tomographic brain images. |
|
|
|
|
|
Auditory
(brainstem) EP recording
Auditory
EP when stimulating from left and right for ipsi- and contralateral
derivations. |
|
|
|
|
|
Recording and analysis of somatosensory EP
3-channel
somatosensory evoked potentials recording. |
|
|
|
|
Neuron-Spectrum-4/EP Delivery Set
·
EEG unit with a stand
·
LED photic stimulator with a stand
·
Set of accessories for EEG recording:
o
Bridge/cup EEG electrode – 25 pcs.
o
Ear EEG electrode – 3 pcs.
o
EEG cable for bridge/ear EEG electrode – 25 pcs.
o
EEG helmet – 3 pcs. (big, medium, small)
·
Neuron-Spectrum-LEP – software for multi-channel long-latency
EP study with brain mapping
·
Neuron-Spectrum-MEP – software and equipment for 4-channel
short- and long-latency EP study:
o
Cup electrode for EP recording with cable – 8 pcs.
o
Pup-jack linker for EP recording – 2 pcs.
o
Set of stimulators for EP recording:
o
Visual stimulator (LED goggles)
o
Auditory stimulator (headphones)
o
Electro stimulating electrode
o
Adapter for pattern-stimulator connection (as a pattern
stimulator, any SVGA computer monitor can be used, but the monitor is
not included in the delivery set and should be bought separately)
o
Patient button
o
Electrode adhesive paste
o
Abrasive paste for skin preparation
·
CD with software
·
User and technical manuals
·
Transportation bag |
|
Extra Delivery Set
·
Electrode cap
·
Needle electrode for intraoperative monitoring – 24 pcs.
·
BrainLoc –
3-D dipole localization of pathologic activity sources software
·
Neuron-Spectrum-Video
– long-term video monitoring system
·
Neuron-Spectrum-EMG – software and equipment for 4-channel EMG
examinations
·
Neuron-Spectrum-ERG – software and equipment for ERG examinations
·
Neuro-MS –
magnetic stimulator for cerebral cortex motor zones and peripheral nervous
system
·
Poly-Spectrum-Rhythm
– software for the examination of vegetative nervous system
Neuron-Spectrum-4/EP Specifications
|
Number of EEG channels |
21 |
|
Number of polygraphic channels |
4 |
|
Number of breath channels |
1 |
|
EEG-Channels: |
|
Sampling rate per channel |
up
to 5000 Hz |
|
Sensitivity |
1
– 500 µV/mm |
|
Input range |
13
mV |
|
High pass filter |
0.05 – 2 Hz |
|
Low pass filter |
15, 30, 75, 100, 150, 200 Hz |
|
A/D converter |
16
bit |
|
Common-mode rejection ratio at 10 Hz frequency |
110 dB |
|
Suppression ratio of power frequency by notch filter |
40
dB |
|
Peak-to-peak noise level measured at 10 kΩ resistance |
0.8 µV |
|
Input impedance, not less than |
100 MΩ |
|
Interchannel damping, not less than |
60
dB |
|
Calibration |
Auto |
|
Control of electrode setting according to impedance measurement |
Yes |
|
Control of ground electrode setting |
Yes |
|
Polygraphic Channels: |
|
Sampling rate per channel |
up
to 40000 Hz |
|
High pass filter |
0.05 – 200 Hz |
|
Low pass filter |
35
– 5000 Hz |
|
Sensitivity |
10
– 10000 µV/mm |
|
Input range |
0.2 – 100 mV |
|
Photic Stimulator: |
|
Stimulus duration |
20
– 1000 ms |
|
Stimulation frequency |
0.1 – 50 Hz |
|
Left / right / double-sided stimulation |
Yes |
|
Pattern-Stimulator: |
|
Stimulation frequency |
1
– 10 s |
|
Pattern size |
4х3, 8х6, 16х12, 32х24, 64х48 cells |
|
Auditory Stimulator: |
|
Stimulation level |
0
– 110 dB |
|
Tone Stimulation: |
|
|
• Frequency |
100 – 2000 Hz |
|
• Stimulus duration |
0.5 – 500 ms |
|
Click Stimulation: |
|
|
• Stimulus duration |
100 – 5000 µs |
|
Stimulation frequency |
0.1 – 50 Hz |
|
Percent of significant / insignificant stimuli |
0
– 50% |
|
Left / right / double-sided stimulation |
Yes |
|
Compression / depression |
Yes |
|
Electrical Stimulator: |
|
Stimulus amplitude |
0
– 100 mA |
|
Stimulus duration |
100 – 1000 µs |
|
Stimulation frequency |
0.5 – 50 Hz |
|
Breath Channel: |
|
Bandpass |
0.05 – 35 Hz |
|
Supply Voltage: |
|
Electronic unit |
5
V DC |
|
Desktop PC-based system |
220/230 V AC (50 Hz) / 110 V AC (60 Hz) |
|
Notebook PC-based system |
220/230 V AC (50 Hz) / 110 V AC (60 Hz) / Int. battery |
|
EEG unit power consumption, not more than |
2.8 VA |
|
Dimensions: |
|
EEG unit total dimensions |
150x200x60 mm |
|
Delivery set total dimensions |
450х450х300 mm |
|
Weight: |
|
EEG unit weight |
0.9 kg |
|
Delivery set weight (without computer and printer, with stands),
not more than |
14
kg |
|
Interface |
USB |
|
Safety |
BF
type |
|
EEG SÝSTEMLERÝNE GERÝ
DÖN |